Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

1. Remove the round bottom flask from the base of the condenser, directly above the hot bath. Inspect the flask to ensure it is clean. 2. Load your sample into the cleaned round bottom flask. 3. Attach the round bottom flask to the condenser. If need be, use vacuum grease located next to the rotary evaporator to create a vacuum seal between he ...

Get More
Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

10. Fill the hot bath with enough DI water for the round bottom flask to sit it. 11. Lower the round bottom flask into the hot bath by either turning the condenser column, or lowering the entire setup. a. To turn the condenser, locate the dark grey knob on near the top of the support. Turn the knob counter clockwise until the knob pops out ...

Get More
Crystallization is used to purify a solid. The process ...

Crystallization is used to purify a solid. The process ...

2. If you used reduced pressure to concentrate solution, use the water aspirator with a TRAP in the line. DO NOT turn off the water until the pressure is released. In general, CLAMP any flask that could conceivably trip over. 3. Do NOT use ebullation if using the Roto-Evaporator. The rotation provides sufficient agitation. Crystallization (review)

Get More
Friedel-Crafts Acylation. Acetylation of Ferrocene.

Friedel-Crafts Acylation. Acetylation of Ferrocene.

4 for ~15 min, then decant into a clean dry 50 mL round-bottom flask and remove the methylene chloride using the rotary evaporator. Perform a TLC analysis of your crude product. Dissolve 1-2 mg of your crude product in ~0.5 mL of methylene chloride and do the same for a …

Get More
Lab Glassware - Rotary Evaporator

Lab Glassware - Rotary Evaporator

50 Liter Rotary Evaporator w/ DLSB-50/40 Low Temp. Coolant Circulation Pump. ... Buchi RE-111 Rotary Evaporator Rotavapor Brinkmann STAND ONLY Excellent Working Condition.115 V. Comes with the stand only. No plate or any other accessories included. 11825. We do allow a 14 day return window on items that are listed with a return policy ...

Get More
How to get the crude extract out of the flask after it was ...

How to get the crude extract out of the flask after it was ...

All Answers (13) After rotatory evaporation, you have to dissolve it in any of your solvent of interest to do further analysis such as DDPH and Total phenolics assay. If …

Get More
CHEM 344 Distillation of liquid mixtures

CHEM 344 Distillation of liquid mixtures

and a flask to hold the condensed liquid (the distillate). Figure 1: Apparatus for a simple distillation. 1.1 The distillation flask The distillation flask is a round-bottom flask. The liquid to be distilled should fill the distillation flask to ~50-60% of its capacity. To promote even heating of the liquid, a boiling chip or a

Get More
Setup of Reflux apparatus - University of California Los ...

Setup of Reflux apparatus - University of California Los ...

Apr 10, 2003 1. Dimension. Make sure that the reaction vessel is not more than half filled to allow enough room for expansion and boiling. 2. Clamps. The entire setup has to be clamped at the neck of the flask (using a proper sized clamp) or at the air condenser in micro-scale using compression caps. It has to hold the entire weight of the entire setup.

Get More
Tips and Tricks for the Lab: Column ... - ChemistryViews

Tips and Tricks for the Lab: Column ... - ChemistryViews

Aug 07, 2012 Rotary evaporator Method: Dissolve the sample in an appropriate solvent. Transfer it to a round-bottomed flask if it is not already in one. Add dry silica to the dissolved sample (approx. 10–20 times the mass of the sample). Swirl or stir gently to ensure all of the silica is suspended within the solution.

Get More
Rotary Evaporation - Chemistry LibreTexts

Rotary Evaporation - Chemistry LibreTexts

Aug 15, 2021 Omission of any of these steps may result in an undesired outcome, e.g: filling the rotary evaporator with tap water when turning off the aspirator before opening the stop cock, bulk transport of your sample into the deepest recesses of the rotary evaporator when disconnecting the flask before opening the stopcock, and broken glassware as well ...

Get More
Photochemical Initiation Of Radical Polymerization ... - JoVE

Photochemical Initiation Of Radical Polymerization ... - JoVE

Concentrate the mixture on a rotary evaporator. Measure the weight of the flask to obtain mass of the non-volatile residue, and obtain an NMR spectrum in CDCl 3. Transfer 1 mL of the benzophenone stock solution to a tared 25-mL round bottom flask containing a stir bar, and dilute with 10 mL of toluene and 3 mL of styrene.

Get More
OChem Lab Final Flashcards - Quizlet

OChem Lab Final Flashcards - Quizlet

d. to the round bottom flask. a. bottom of the condenser. How much should you fill the reaction flask before refluxing? a. as full as possible ... When using a rotary evaporator, you should always check the flask for cracks before filling it with your solution. a. True b. False. a. True

Get More
Extraction in Theory and Practice (Part I)

Extraction in Theory and Practice (Part I)

Dec 30, 2013 c. Removal of an amine Depending on the chain length, amines might or might not be soluble in water i.e., propylamine is miscible with water (log K ow =0.48), triethylamine displays a limited solubility at room temperature (17 g/100 mL, log K ow =1.44), while tributylamine hardly dissolves at all (0.37 g/100 mL, log K ow =4.60). Amines are basic and can be converted to …

Get More
Distillation - Wired Chemist

Distillation - Wired Chemist

Distillation. Simple distillation is a procedure by which two liquids with different boiling points can be separated. Simple distillation (the procedure outlined below) can be used effectively to separate liquids that have at least fifty degrees difference in their boiling points. As the liquid being distilled is heated, the vapors that form ...

Get More
Extraction of Chlorophyll from Fresh Spinach

Extraction of Chlorophyll from Fresh Spinach

Filter a small amount of the combined organic extracts into a 250-mL round bottom flask using a funnel. Use a rotary evaporator to remove the solvent, then filter more organic extract into the round bottom flask and continue the evaporation process. Do not let the temperature of the bath exceed 45 (C, although a temperature of 25-35 (C should ...

Get More
158 questions with answers in SOXHLET EXTRACTION ...

158 questions with answers in SOXHLET EXTRACTION ...

Jan 06, 2022 Answer. The temperature of soxhlet extraction is entirely determined by the selected solvent because it is the boing point of that specific solvent. Any temperature below the B.P. results in a ...

Get More
Why should a distillation flask only be filled one thirds ...

Why should a distillation flask only be filled one thirds ...

Jan 29, 2009 If the neck of your flask is short, you don't want to fill the flask too high (more than about 1/2), or else liquid from the flask will enter your distilling tube and get distilled out when you heat it. nbsp;Remember the idea of a distillation is to heat up your substance to the vapor phase and let the vapor diffuse toward the distillation tube so that only purified product …

Get More
Laboy Glass 1000mL Single Neck Round Bottom Boiling Flask ...

Laboy Glass 1000mL Single Neck Round Bottom Boiling Flask ...

Laboy Glass 1000mL Single Neck Round Bottom Boiling Flask Heavy Wall with 24/40 Joint Heating ... In a reflux process,it’s used as a reaction flask with a reflux condenser.It is also used as a Distilling flask in rotary evaporators. ... BUY WITH CONFIDENCE----100% 90 DAY MONEY BACK GUARANTEE simply return for a full refund,no question asked ...

Get More
Laboy Glass 500mL Single Neck Round Bottom Boiling Flask ...

Laboy Glass 500mL Single Neck Round Bottom Boiling Flask ...

Laboy Glass 2000mL Single Neck Round Bottom Boiling Flask Heavy Wall with 45/50 Joint Heating Distillation Reaction Receiving Flask Organic Chemistry Lab Glassware ... The round bottom flask has larger heating surface than the flat bottom flask and can be heated evenly.It is usually used in the laboratory operation requiring high temperature ...

Get More
Types of Chemistry Flasks: A Complete Guide

Types of Chemistry Flasks: A Complete Guide

Mar 05, 2020 Pear-shaped flasks are used for evaporating solutions to dryness post-synthesis using a rotary evaporator, the ’rounded V’ shape of the flasks enables solid materials to be scraped out more efficiently than from a round-bottomed flask. Also, collecting liquids using a syringe, it’s easier with the pear-shape!

Get More
Esterification Reflux Purpose Reaction What is ...

Esterification Reflux Purpose Reaction What is ...

Mar 08, 2022 Reflux is a laboratory technique used to heat a mixture without losing much solution. The purpose of refluxing a mixture is to speed up and/or induce the reaction occurring. A reflux setup is used ...

Get More
Rapid Synthesis of Nucleoside ... - Current Protocols

Rapid Synthesis of Nucleoside ... - Current Protocols

May 11, 2020 9. Dissolve the solidified product in 30 ml anhydrous MeCN and transfer the liquid into a precisely weighed 100-ml single-neck round-bottom flask. Wash the 500-ml flask with 20 ml anhydrous MeCN to complete the transfer into the 100 ml flask. 10. Evaporate the solvent under reduced pressure by using a rotary evaporator. 11.

Get More
Rotary Evaporation in the Kitchen - Cooking Issues

Rotary Evaporation in the Kitchen - Cooking Issues

May 19, 2009 Fill water bath (usually 2/3 full) with warm to hot water, set the temperature and turn it on. Put the thermometer from the rotovap unit into the water bath. Clean the vapor duct area and install the vacuum seal. Install a DRY evaporation flask. Close off (seal) the receiving flask/pump takeoff area.

Get More
5-2000ml Quickfit Joint Lab Glass Rotary Evaporator Flask ...

5-2000ml Quickfit Joint Lab Glass Rotary Evaporator Flask ...

New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is ... Read more about the condition New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer …

Get More
Solvent Removal

Solvent Removal

Place the solution to be evaporated in a round bottom flask, then connect the flask to the rotovap. Do not fill the flask more than about one-third full. Use a Keck clip to secure the flask to the apparatus. Make sure the water flow to the cooling coils is turned on. Turn on the motor so that the flask rotates. Usually the flask containing the ...

Get More
Lab Glassware - Laboratory Glassware - 3

Lab Glassware - Laboratory Glassware - 3

Round Bottom Flask. 25 mL 8. Round Bottom Flask. 50 mL 9. Round Bottom Flask. 100 mL 10. Round Bottom Flask. 250 mL 11. Round Bottom Flask. 500 mL 12. Separatory Funnel. 125 mL 13. ... Buchi Rotary Evaporator Glass Outer Sleeve 20.75 Lab Glassware Condenser ... Seller assumes no liability for any reason for using this product. I ONLY SHIP TO A ...

Get More
How to set up a reflux apparatus

How to set up a reflux apparatus

round bottom flask. Make sure the glass joints are lightly greased with silicon. • Clamp the reflux condenser to the iron stand in the upright position. 3) Setting up the tubes • Connect one end of one rubber tubing with the water tap and the other end …

Get More
Flask StonyLab United States

Flask StonyLab United States

StonyLab provides not only high quality labware and glassware, but also metal catalyst, chemicals, and custom synthesis service. ... Rotary Evaporator; Short Path Distillation; Spray Dryer; Temperature Control Equipment; Ultrasonic Cleaner; ... Round Bottom - Accessory. Funnel - Buchner - Conical Separatory - Glass Funnel - Powder

Get More
Freeze Drying / Lyophilization Information: Basic Principles

Freeze Drying / Lyophilization Information: Basic Principles

Sublimation in the freeze drying process can be described simply as: FREEZE - The product is completely frozen, usually in a vial, flask or tray. VACUUM - The product is then placed under a deep vacuum, well below the triple point of water. DRY – Heat energy is then added to the product causing the ice to sublime.

Get More
Solved EXPERIMENTAL PROCEDURE Day 1 HBr Addition to 1 ...

Solved EXPERIMENTAL PROCEDURE Day 1 HBr Addition to 1 ...

The 25 mL round bottom flask must be 100% dry, using a wet flask is unsafe and also; Question: EXPERIMENTAL PROCEDURE Day 1 HBr Addition to 1-Hexene Obtain a 50 mL beaker and fill it about half full of water to rinse the pipette tip in the hood. You should also collect a 150 mL.beake, sir plate, a Teflon stoper,a sir bar and a clean and dry 25 ...

Get More
A SN1 Reaction: Synthesis of tert-Butyl Chloride

A SN1 Reaction: Synthesis of tert-Butyl Chloride

The dried solution is then filtrated by gravity to a round bottom distillation flask. Care should be taken to hold the funnel over the round bottom flask such that the air leaves as the filtrate flows to the flask in order to avoid over- pressure in the distillation flask.

Get More
Exp 1: Separating Cyclohexane and Toluene by ... - Quizlet

Exp 1: Separating Cyclohexane and Toluene by ... - Quizlet

Through the use of simple fractional distillation you will separate two miscible liquids. (cyclohexane and Toluene) 2. Once separated, you will compare the efficiencies of simple fractional distillation. the process of vaporizing a liquid, condensing the vapor, and collecting the condensate in another container.

Get More
Ozonolysis of Alkenes: Principle and Applications ... - JoVE

Ozonolysis of Alkenes: Principle and Applications ... - JoVE

Transfer the filtrate to a round-bottomed flask. Again remove the solvent with a rotary evaporator to obtain vanillin as yellow to white crystalline needles. Calculate the percent yield, determine the melting point, and obtain a proton NMR spectrum of the product. Vanillin is obtained as a white crystalline solid.

Get More
Lab Glassware - Flask Lab - 5 - Trout Underground

Lab Glassware - Flask Lab - 5 - Trout Underground

Used Bantam ware glass round bottom flask with a volume of 250 ml 3 neck- 14/20 side joints and 19/22 central joint. There are no visible dents or scratches on the item. The new cost $100. Manufactured in USA. Designed for chemical or biochemical work. Made from heat-resistant borosilicate glass. Round bottom allows uniform heating of liquid.

Get More
Ochem lab 2325 Flashcards Quizlet

Ochem lab 2325 Flashcards Quizlet

Using a round bottom flask with a visible crack for a high heat refluxing experiment ... only the small amount you need for each trituration and keep it on the opposite side of the hood as the heater. You should weigh out the largest round bottom flask that you have with the aid of a cork ring. ... The hexanes will be evaporated off on a rotary ...

Get More
Volume measuring for liquids De Qumica

Volume measuring for liquids De Qumica

Volumetric flask. It is a type of flask with a high neck, narrow and flat bottom that is used to accurately measure a given volume of liquid. They have a mark on the neck which indicates how far the liquid level must reach to reach the volume corresponding to the capacity of the flask. The liquid forms a curvature in the neck called meniscus ...

Get More
Solved When using a rotary evaporator the water bath is ...

Solved When using a rotary evaporator the water bath is ...

Wash the layer with 15 mL of saturated sodium chloride solution. Drain the methylene chloride layer into a clcan, dry Erlenmeyer flask. layer. Let the layer dry over the drying agent for several minutes. weighed 100 mL round bottom flask Evaporate the solvent using a rotary evaporator. Weigh the solid in the flask and calculate the mass of the ...

Get More
OCHEM Lab Final Flashcards Practice Test - Quizlet

OCHEM Lab Final Flashcards Practice Test - Quizlet

When using a rotary evaporator, you should always check the flask for cracks before filling it with your solution. True Rotary evaporators have many glass components and care must be taken not to exert too much force on any part of the system.