D-RE-1010 D-RE-1020 D-RE-1050 rotary evaporator are the laboratory equipment sold by our company, with 10L 20L 50L capacity optional, and Power supply includes 220V50HZ and 110V 60HZ.

How to Set Up A Rotary Evaporator? - WKIE Lab

How to Set Up A Rotary Evaporator? - WKIE Lab

10. To stop the system’s evaporation process, reverse all the above steps by opening the stockcock, stopping the rotation, turning off the vacuum, and lifting the mask off the water bath. The residue formed at the bottom of the flask should contain the compound. Please Feel Free To Fill In The Form To Get Free Quote On WKIE LAB Rotary Evaporator:

Get More
SOP STANDARD OPERATING PROCEDURE - UNE

SOP STANDARD OPERATING PROCEDURE - UNE

13. Turn off cooling water. 14. Ensure speed dial is to zero and turn off motor switch the rotary evaporator. 15. If finished for the day turn off water bath and power points, and leave the rotary evaporator and work area in a safe, clean and tidy state. Section 4 – …

Get More
1 L Rotary Vacuum Evaporator Instruction Manual

1 L Rotary Vacuum Evaporator Instruction Manual

3) Attach Main and Sub-Vacuum Seals to the glass Rotary Joint. The two brown parts will touch and the tapered edge of the Sub-Seal will face outward. 4) Push Rotary Joint Ring into Driving Unit (it will snap into place). 5) For S Model, proceed to Step 7. Attach Condenser Support (metal rod, knob bolt) to the Driving Unit. Leave some room for ...

Get More
ROTARY EVAPORATOR RE550 -

ROTARY EVAPORATOR RE550 -

4. Set the cooling condenser nut, coil ring and vacuum seal to the condenser or condenser connector. 1. Remove the cooling condenser nut and coil ring on the left side of motor. 2. Connect the cooling condenser nut and then the coil ring to the condenser or condenser connector (which ever applies). Be sure to put the nut on first.

Get More
APPENDIX 7 : How to use the rotary evaporator

APPENDIX 7 : How to use the rotary evaporator

5 Turn on the vacuum with the check valve near the sink. 6 Close the stopcock at the top of the rotary evaporator condenser. 7 While you are still holding the flask, turn the dial for the rotary evaporator motor to rotate the flask, slowly at first, then at a higher speed so that foaming of the solvent is kept at a safe limit. A good setting is ...

Get More
Rotary evaporator - Efficient vacuum distillation equipment

Rotary evaporator - Efficient vacuum distillation equipment

A complete rotary evaporation evaporator requires the heating of a water bath, the vacuum environment provided by the vacuum pump, and the condensing environment created by a cryopump and a condensation coil to collect materials. These three main devices can achieve the best operating conditions, and naturally can improve the efficient operation of the rotary …

Get More
Rotary Evaporators - Marshall Scientific

Rotary Evaporators - Marshall Scientific

A rotary evaporator (also known as a rotovap) is a device used to turn the liquid form of a chemical into its gaseous form. The liquid is evaporated, or vaporized into a gas that is then condensed back into its pure liquid form to be captured in a container. Marshall Scientific sells all of the necessary components to have a running and fully ...

Get More
Laboratory Rotary Evaporaors - McMaster University

Laboratory Rotary Evaporaors - McMaster University

Before continuing follow these steps; ... Turn on the water to the condenser slowly and ensure that it is draining into the appropriate sink. Make sure that the vacuum valve at the top of the condenser is in the ‘open’ position. ... High Vacuum Rotary Evaporation- BUCHI diaphragm or …

Get More
EV400 SERIES - LabTech

EV400 SERIES - LabTech

Condenser Receiving Flask Evaporation Flask Heating Bath Temp.Controller . EV400 SERIES – User Manual 6 Specifications LabTech rotary evaporator system, in combination with LabTech chiller and vacuum pump, provides a total solution package to customer who wants to have an efficient, fast and gentle ... turn off the instrument and disconnect ...

Get More
How to Use a Rotary Evaporator? - Rotovap

How to Use a Rotary Evaporator? - Rotovap

Dec 20, 2019 Switch on the condensate water, switch on the power supply, connect the evaporator with the host machine (do not let go), open the vacuum pump to reach a certain vacuum degree before releasing your hand. Method to adjust the host height: Press down the pressure bar at the bottom of the heating tank, adjust the radian left and right to make the ...

Get More
How to Use a Rotary Evaporator? - Rotovap

How to Use a Rotary Evaporator? - Rotovap

Dec 20, 2019 There are some instructions that can be followed in order to use rotary evaporators better and more properly. Connect the hose to the condenser tap. Connect the vacuum pump with the vacuum rubber hose for vacuuming. Fill the tank with water (preferably pure water). If you use tap water, leave it for a day or two before using .

Get More
Rotary 1 Evaporators - WIGGENS

Rotary 1 Evaporators - WIGGENS

Easy to operate using the state-of-the-art turn push controller and 4.3 touch screen, widely and easy to read. ... * Rotary Evaporator Strike 280 * Condenser * Evaporting Flasks: 50,100,250,500,1000mL ... Rotary Evaporators C410 / C510 Vacuum pump CSH410 / CSH510 Solvent Recovery Systems CSC410 / CSC510 Solvent Recovery Systems

Get More
Laboratory Rotary Evaporaors - McMaster University

Laboratory Rotary Evaporaors - McMaster University

Hold the condenser with your left hand cradling it from the bottom (once the knob is unlocked the condenser will fall in a downwards motion). Turn the grey knob with your right hand in a counter clockwise direction (this will unlock the system and allow you to adjust it).

Get More
The Rotary Evaporator

The Rotary Evaporator

How the rotary evaporator works is summarized below. oC CH2Cl2 CH3OH 200 400 800-60 -40 -20 0 20 40 60 80 760 Torr 41oC 65oC 0 ... condenser to condense the volatile solvent on the condenser coils and to prevent, as much as ... Turn off the water aspirator. c. Remove the round bottom flask. A twisting motion is helpful.

Get More
Laboratory Technique - Rotary Evaporator Optimization ...

Laboratory Technique - Rotary Evaporator Optimization ...

Jan 01, 2020 Ensure there is enough water to come up almost to the level of the rotary flask neck, covering 30-40% of the flask when fully lowered. Turn on the refrigeration unit to its lowest possible setting, below 0C is ideal. Turn on the vacuum pump. Set flask rotation to about 100 revolutions per minute (RPM).

Get More
Rotovap Distillation: What Is A Rotary Evaporator? BVV

Rotovap Distillation: What Is A Rotary Evaporator? BVV

Jul 21, 2017 Connect vacuum pump to cold trap and cold trap to rotovap vacuum port. Turn on heat bath and set to 40C (113F). Once heat bath and coil have reached the desired temperature, turn on rotovap motor and set speed to approximately 100 RPM. Start vacuum pump and allow it to pull down for a few minutes before beginning injection.

Get More
Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

Make sure the vacuum pump located next to the rotary evaporator is connected to the condenser. Make sure the release valve at the top of the condenser is turned to the closed position. 9. Turn on the vacuum. The gauge on the vacuum pump should read 27 in Hg if the system is not leaking. 10.

Get More
Home Environmental Health Safety UCI

Home Environmental Health Safety UCI

Once the evaporation is complete conduct the same steps in the reverse order: turn off the hot water bath, remove the flask from the water, stop the rotation, turn off the vacuum, slowly open the stopcock to vent the system (remove residual vacuum) while holding the flask (to avoid it falling and breaking), and remove the flask.

Get More
Rotovap Startup

Rotovap Startup

Open pressure valve on condenser unit. 3. Turn off vacuum pump. • Always vent to atmospheric pressure before turning off vacuum pump! • This is the same for any vacuum system. 4. Turn off rotary spinner. 5. Remove flask. 6. Turn off water bath and chiller unless you plan to use again in the near future. Rotovap Tips A. To avoid bumping ...

Get More
Industrial Rotary Evaporator Solvent Recovery System

Industrial Rotary Evaporator Solvent Recovery System

Our industrial-scale rotary vacuum evaporator is a turn-key solvent recovery system trusted by chemists and botanical extraction processors in both research and commercial laboratory settings. Based on innovative self-cooling technology, our smart cooling system is both eco-friendly and efficient. The EcoChyll X7 continuous cooling system is ...

Get More
Rotary Evaporator RE400 RE400P RE401 RE401P

Rotary Evaporator RE400 RE400P RE401 RE401P

Place the Diagonal condenser10(RE400/P) or the Condenser adaptor11(RE401/Pand RE402/P) over the vapour tube so that it butts up to the vacuum seal. Ensure the spherical joint points downwards and support the diagonal condenser as you …

Get More
Rotary Evaporator 50l Automatic Lift With Recirculating ...

Rotary Evaporator 50l Automatic Lift With Recirculating ...

Rotary Evaporator 50L Automatic with chiller and ARV 30 Pump: Rotary Evaporator 50L Automatic Lift: Our 50 Litre Rotary evaporators are perfect for removing unwanted solvents from extracts using evaporation as a gentle yet efficient way of performing this task. Our Rotary evaporator has a motor which is digitally controlled that works between 0-120rpm this allows …

Get More
The working principle and use method of rotary evaporator

The working principle and use method of rotary evaporator

Sep 09, 2021 The solvent vapor is cooled by the glass condenser and recovered in the collection bottle, which greatly improves the evaporation efficiency. ... which is connected to the vacuum pump hose for vacuuming. 3. Turn the speed control knob to the minimum before starting the machine, press the power switch and the indicator light is on, and then ...

Get More
Method and precautions during use of rotary evaporator ...

Method and precautions during use of rotary evaporator ...

Sep 24, 2014 7. After the evaporation is completed, first turn off the speed switch and the temperature control switch, press the lower pressure rod to raise the main unit, then close the vacuum pump, and open the vent valve above the condenser to make it open to the atmosphere, remove the evaporation bottle, and the evaporation process ends.

Get More
Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure - Rotary Evaporator

the rotary evaporator control panel. 15. Use the dial on the rotary evaporator control panel to set the desired spin speed of the condenser. 16. If the desired evaporation should be timed, press the timer button on the rotary evaporator control panel and use the dial to set a time in minutes, or press the int

Get More
Rotatory Evaporator Working Principle - Rotary Evaporation ...

Rotatory Evaporator Working Principle - Rotary Evaporation ...

The rotatory evaporator working principle is that the boiling point of liquids lowers on decreasing their pressure. This allows the solvent to vaporize at lower temperatures than when boiled in a normal atmosphere. You should choose a vacuum pump for your rotavap that will guarantee an improved evaporation efficiency.

Get More
How To Use A Rotary Evaporator / Rotovap? - WKIE

How To Use A Rotary Evaporator / Rotovap? - WKIE

The standard rotary evaporator uses a sparkless induction, variable-speed motor that typically spins at 0-220 rpm. These motors provide constant and high torque. To activate the aspirator vacuum, many models come with an on/off control that you turn on or off via a stopcock which is positioned over the condenser.

Get More
Operation of the Rotary Evaporator (Rotovap)

Operation of the Rotary Evaporator (Rotovap)

To close the system and thus activate the vacuum, turn the stopcock knob at the far end of the rotovap to align it with the vacuum (ie. turn until the arrow on the knob points straight down towards the attached tubing ie. knob is pointing to the “ON” position). The system is now under reduced pressure. (below) OFF ON

Get More