Pumping Off Solvent Using Rotovap

For Reference Price: Get Latest PriceGet Latest Price

D-RE-1010 D-RE-1020 D-RE-1050 rotary evaporator are the laboratory equipment sold by our company, with 10L 20L 50L capacity optional, and Power supply includes 220V50HZ and 110V 60HZ.

Use of the Rotovap - uwindsor.ca

Use of the Rotovap - uwindsor.ca

7. Make sure the solvent receiver is empty. 8. Ensure that you know what pressure to lower the rotovap to based on the chart. 9. Turn on the pump, decrease the pressure to the target. 10. Use up down switch to make the flask is submerged in the bath water. 11. Turn on the rotation. 12. Adjust the speed of rotation.

Get More
Standard Operating Procedure Task: Rotary Evaporation

Standard Operating Procedure Task: Rotary Evaporation

air using the ground glass joint. Turn off the vacuum pump using the switch on the pump, turn off the water bath heat if used, and turn off the rotovap by pressing the appropriate power buttons and turn off the water at the tap 12. Empty the collection flasks (both attached to the rotovap and the vacuum pumps after every use! Notes: • Be ...

Get More
Selecting a Suitable Chiller for Your Rotary Evaporator ...

Selecting a Suitable Chiller for Your Rotary Evaporator ...

Apr 04, 2019 It may even flood the pump, causing irreparable damage. Plus, if you have an over-temperature alarm on your chiller, setting too low a temperature may cause the alarm to sound and the chiller to shut off completely. 2. Pump Pressure. Another important factor to consider is the maximum pressure of your chiller pump. When subjected to too high a ...

Get More
Selecting a Suitable Vacuum Pump for Your Rotary ...

Selecting a Suitable Vacuum Pump for Your Rotary ...

Apr 04, 2019 Applying vacuum using a pump is either helpful or necessary in most rotovap applications as it reduces the pressure within the system. This lowers the boiling temperature of the solvent resulting in faster evaporation and safer rotary evaporator operation. When composing a rotary evaporator setup, not just any pump will be up to the task.

Get More
How to prevent losing solvent into the vacuum pump in ...

How to prevent losing solvent into the vacuum pump in ...

Apr 07, 2015 So I'm asking for answers from people who actually use the things. A rotovap typically uses a cold condenser to condense the solvent into a collection flask. But the distillation is typically done under weak vacuum as well. So the solvent sitting in the collection flask seem susceptible to re-vaporizing and getting sucked into the vacuum pump.

Get More
How to Operate a Rotovap? - Lab Instruments - Henan ...

How to Operate a Rotovap? - Lab Instruments - Henan ...

Apr 26, 2017 15. Continue to rotovap as long as necessary. 16. If you need to break the vacuum to the pump to discard solvent from the trap or add ice to the dry ice trap, open the valve and leave the vacuum pump running. Discard solvent/add ice, shut valve and continue with rotary evaporation of sample. 17.

Get More
How does a Rotary Evaporator Remove Solvent? - Rotovap

How does a Rotary Evaporator Remove Solvent? - Rotovap

Aug 09, 2019 Fill the rotovap cold traps with dry ice. Attach a glass “bump trap” to prevent any solution from entering the main part of the rotovap. Secure with a clip. Connect the flask and bump trap to the adaptation part with a clip. Lower the flask into the water bath, preventing the flask from disconnection. 2.

Get More
How to Clean Your Rotary Evaporator Blog -

How to Clean Your Rotary Evaporator Blog -

Dec 16, 2019 If you’re using an oil-free pump such as a membrane pump, it could become flooded with solvent. If this happens, you’ll need to keep it running to help clear the solvent and dry it out. In either case, in the long run, you’re better off skipping this cleaning method altogether and dismantling your setup for cleaning instead. 2.

Get More
The Rotovap: Fundamentals and Trends in Rotary Evaporator ...

The Rotovap: Fundamentals and Trends in Rotary Evaporator ...

How to Use a Rotary Evaporator. The concept of the rotovap entails motorized rotation of a solvent under reduced pressure. Lowering the pressure by the use of a vacuum pump effectively reduces the boiling point of the solvent. Combined with heating, the newly evaporated solvent travels to a condenser vessel or coil where vapor is then converted ...

Get More
Standard Operating Procedures: Bart Laboratory

Standard Operating Procedures: Bart Laboratory

If the power has gone out, cap all reactions and turn off the main switch. If the power is still on, perform the following steps: a. Close the catalyst b. cap all reactions c. Turn off the chambers d. Shut down the vacuum pump e. Turn off the main switch 3. Shut down the Schlenk lines in the hoods by closing off reactions and sealing off vacuum

Get More
Rotovap Distillation: What Is A Rotary Evaporator? - BVV

Rotovap Distillation: What Is A Rotary Evaporator? - BVV

Jul 21, 2017 Match the input speed to the output speed by injecting the same amount of liquid dropping off the coil (into the receiving flask) into the rotovap. ... vacuum regulator. It maintains a specified vacuum level throughout the evaporation process. This pinpoints the specific solvent boiling points, speeds up processing, and prolongs the vacuum pump ...

Get More
Standard Operating Procedure: Rotovaps

Standard Operating Procedure: Rotovaps

Jun 06, 2016 Before using the rotovap, operator should be familiar with the various rotovap components and definitions. First take your sample solution (in round bottom flask—volume half full) to the rotovap you wish ... seconds to purge the pump from any solvent prior to turning off the pump (if using the belt drive pump, ...

Get More
How to use a rotovap -

How to use a rotovap -

Mar 26, 2019 Firstly, ensure the receiving flask is empty. To empty the flask, carefully remove the clip and pour any solvent into the appropriate waste bottle. Carefully attached the receiving flask and secure with the clip. Ensure the air bleed is open. Turn on the rotary evaporator. Turn on the water bath and adjust to a suitable temperature.

Get More
How to use a rotovap -

How to use a rotovap -

Mar 26, 2019 To relieve the bumping, reduce the vacuum using the air bleed. Once the solvent has evaporated, the appearance of the flask will depend on the physical state of the product i.e. the residue may be a solid or an oil. When finished, raise the flask and turn off the rotation. Open the air bleed and turn off the vacuum pump.

Get More
AI Rotovaps for Solvent Recovery Fractional Distillation ...

AI Rotovaps for Solvent Recovery Fractional Distillation ...

Nov 04, 2015 Our new SolventVap rotary evaporators are built for making clean, clear concentrates, and we offer 4 different sizes that match any lab’s production needs or budget. If you have any questions or comments about our rotary evaporators and their usage, leave us a comment below, link up with us on Instagram and Facebook, or call 888-988-0899 to ...

Get More
How to use a rotary evaporator -

How to use a rotary evaporator -

Nov 09, 2018 1. The solvent collection flask of the unit should always be emptied prior use to prevent accidentally mixing of incompatible chemicals. SAFETY FIRST! 2. The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated).

Get More
How to Select a Pump for Rotary ... -

How to Select a Pump for Rotary ... -

Oct 17, 2018 Two point or on/off vacuum control allows the vacuum in the system to cycle between a high and low set point by turning the pump on and off. This method allows you to leave the process unattended once the min/max settings are determined. Adaptive vacuum control provides the best results in terms of separation, speed and solvent recovery, and ...

Get More
Buchi 20/40/60 rule for Rotary Evaporators

Buchi 20/40/60 rule for Rotary Evaporators

Optimal Distillation parameters for a rotary evaporator vary according to solvent in use: 1. Set water bath temperature to 60oC – It does not need to be higher! 2. The cooling water temperature should be below 20oC. 3. Adjust the needed vacuum for a solvent boiling point of 40oC according to list below. Reference: Buchi: List of Solvents

Get More
Things to keep in mind before using the rotavapors

Things to keep in mind before using the rotavapors

pump. 7) Once the solvent has been removed, vent the rotovap, turn the vacuum off, and turn off the heating of the water bath. 8) Remove the sample and empty the collection flask. 9) Please make sure, the rotovap is clean when you are finished. 10) In case of solvent spills in the water bath, please change the water, clean it

Get More
rotary evaporator distillation: operation steps of rotary ...

rotary evaporator distillation: operation steps of rotary ...

Recall from general chemistry that vacuum reduces the boiling point of the solvent, so significantly lower temperature is needed to evaporate the solvent using a rotovap than at STP. Adjust the vacuum setting as needed. When all solvent has been removed turn off the vacuum and return the flask to atmospheric pressure. Stop the rotation.

Get More
Rotary Evaporation to Remove Solvent Organic Chemistry ...

Rotary Evaporation to Remove Solvent Organic Chemistry ...

Rotary evaporation is a technique commonly used in organic chemistry to remove a volatile solvent from a non-volatile compound of interest. Invented by Lyman C. Craig in 1950 the rotary evaporator, or rotovap, gently removes solvents from compounds using heat combined with reduced pressure to evaporate, dry, and purify samples for further ...

Get More
Use of rotovap vacuum pump in laboratory for cbd

Use of rotovap vacuum pump in laboratory for cbd

Rotary flask into the water 1/3-1/2. After using, please power off. 4. Rotation: open the control box switch, can adjust knob to the optimal evaporation speed. Pay attention to avoiding the water resonance wave. 5. Connect to the cooling water. 6. Recovering solvent: turn off the vacuum pump, open feeder switch, gas, release solvent of ...

Get More
Rotovap Startup - csustan.edu

Rotovap Startup - csustan.edu

Rotovap Shutdown 1. Raise unit out of water bath. 2. Open pressure valve on condenser unit. 3. Turn off vacuum pump. • Always vent to atmospheric pressure before turning off vacuum pump! • This is the same for any vacuum system. 4. Turn off rotary spinner. 5. Remove flask. 6. Turn off water bath and chiller unless you plan to use again in ...

Get More
Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet - UMass Amherst

solvent) and clog traps. Water aspirators should not be used as these can allow solvent vapors to enter drains and waste large volumes of water. 5. Check all glassware for visible chips, cracks or scratches before using. Handle glassware with care at all times. 6. Always use a cold trap in between the rotovap and the pump. Never use a liquid

Get More
How do organic chemists remove solvents with high boiling ...

How do organic chemists remove solvents with high boiling ...

The procedure is done at reduced pressure (either water aspirator, ~25 mm Hg, or vacuum pump ( 0.1 mm Hg) and the application of heat (water bath kinds of temperatures). There’s a number of tricks you can use, depending on the solubility of your compounds.

Get More
What is the best method of removing solvents like ...

What is the best method of removing solvents like ...

This includes rapid setup time and evaporation, complete access to the flask interior for product removal, simplified process temperature indication and control, and simplified continuous solvent ...

Get More
USA Lab 50L Dual Setup Explosion Proof Rotary Evaporator ...

USA Lab 50L Dual Setup Explosion Proof Rotary Evaporator ...

USA Lab 50L Rotary Evaporator Turnkey Rotovap RE-1050 w/ Vacuubrand MD 4C NTThe USA Lab 50L RE-1050 Series Rotary Evaporator Turnkey Kit recovers solvents efficientlynbMSRP: $18,249.00Was:Now:$15,899.00 - $17,899.00. The USA Lab 50L RE Series Rotary Evaporator recovers solvents efficiently and fast. This unit p.

Get More
Solvent Removal -

Solvent Removal -

Use a Keck clip to secure the flask to the apparatus. Make sure the water flow to the cooling coils is turned on. Turn on the motor so that the flask rotates. Usually the flask containing the solution to be evaporated is warmed by a water bath; consult your TA to see if it is necessary. Make sure the vent at the top of the cooling coils is closed.

Get More
Concentrating Extract in a Rotovap - VACUUBRAND

Concentrating Extract in a Rotovap - VACUUBRAND

Using a variable speed vacuum pump with control will automatically maintain the right amount of vacuum depth to optimize the process, prevent loss of concentrated extract, and help maximize solvent recovery. Once the winterized material has been filtered separating out unwanted waxes, fats and lipids, the remaining extract can be concentrated ...

Get More
How to evaporate out water and methanol by using rotary ...

How to evaporate out water and methanol by using rotary ...

We are measuring the phenolic compounds in our plant and using methanol/water 60/40 as the extraction solvent. The procedure we used in a paper …

Get More